VICTRIX PRO 35 V2 EU
Wall-hung modular condensing boiler for heating only
prompt answers within 24 hours.
Technical data VICTRIX PRO 35 V2 EU |
|
---|---|
Code | 3.034431 |
custom | Array |
custom2 | Array |
C.H. Energy class | A |
Heat output ref. 80-60°C kW | 33,9 |
Heat output ref. 50-30°C kW | 36,9 |
Efficiency at nominal heat output ref. 80-60 °C | 97,0% |
Efficiency at nominal heat output ref. 50-30 °C | 105,8% |
Dimensions (HxWxD) mm | 851 (985) x 440 x 499 |
Modulating heat output | 10 - 100% |
Technical data VICTRIX PRO 35 V2 EU |
|
---|---|
Code | 3.034431 |
Product plus | HYDROGEN READY 20% |
Product plus | BIM READY |
C.H. Energy class | A |
Heat output ref. 80-60°C kW | 33,9 |
Heat output ref. 50-30°C kW | 36,9 |
Efficiency at nominal heat output ref. 80-60 °C | 97,0% |
Efficiency at nominal heat output ref. 50-30 °C | 105,8% |
Dimensions (HxWxD) mm | 851 (985) x 440 x 499 |
Modulating heat output | 10 - 100% |
Wall hung, modular condensing boiler for heating only.
Wide modulating ratio up to 5 boilers in cascade installation, high performances with reduced consumption thanks to the 1:10 modulation range and high efficiency, the new VICTRIX PRO V2 is the ideal solution for light commercial solutions in residential and commercial buildings. The new design, compact and linear, with a vertical sliding door protecting the control board, makes its installation easy even in residential buildings (according to the current regulations in force in each country).
VICTRIX PRO V2 can be used on the appropriate supporting modulation frame for floor standing installations. Certified for indoor and outdoor installations, even in unsheltered areas thanks to the IPX5D electric protection, the boiler is supplied with the -5 °C anti-freeze kit as standard.
Thanks to low emissions of carbon monoxide (CO) and nitrogen oxide (NOX), VICTRIX PRO V2 belongs to class 6, the most environmentally-friendly class established by the European standards (UNI EN 297 e UNI EN 483).
The new VICTRIX PRO V2 can work with natural gas, LPG and up to 20% blend of hydrogen.
CRONO 7 (weekly digital chronothermostat) Cod.3.021622
ON/OFF room thermostat.
CRONO 7 WIRELESS (wireless weekly digital chronothermostat) Cod.3.021624
Wireless ON/OFF room thermostat.
Cascade and zone regulator kit Cod.3.034119
It can manage 3 water distribution zones plus an external storage tank unit
and thermal solar for DHW production, both in standalone and cascade
configurations. It includes power supply connection for installation on a DIN
rail.
Clip-in for VICTRIX PRO V2 Cod.3.034122
To be used together with Cascade and Zones regulator kit (1 for each boiler).
Expansion kit for Cascade and Zones regulator kit Cod.3.034124
To be used to manage 1 additional zone (direct or mixed) up to a maximum
of 5.
External probe Cod.3.015266
For single installation of VICTRIX PRO V2.
For MAGIS COMBO V2, MAGIS PRO V2, MAGIS COMBO PLUS V2, MAGIS HERCULES PRO, MAGIS HERCULES PRO MINI/EH, MAGIS HERCULES MINI HYDRO, TRIO PACK ELECTRIC, TRIO HYDRO system ELECTRIC and MAGIS M/EH.
External probe kit (for cascade installation) Cod.3.024511
Paired with cascade and zone regulator kit, it optimizes energy
consumption by adjusting the plant delivery temperature for variable
temperature functioning
Flow probe kit Cod.3.015267
To be located on the delivery side of the plant, after the hydraulic
separator, it allows the cascade and zone regulator to manage the
delivery temperature of the plant or of the mixed zones available
Remote control for single VICTRIX PRO V2 Cod.3.020358
This is a modulating control unit that serves to optimize climatic
management of the temperature in rooms.
It can only be used on systems with a single temperature control.
System delivery probe kit for the boiler VICTRIX PRO V2 Cod.3.024245
Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.
Tele-management kit 2.0 Cod.3.034121
It works together with the Cascade and Zones regulator kit. It allows remote
management of the device with a dedicated APP.
Zone manager kit Cod.3.034120
Modulating temperature control, backlit display and remote management of
the zone. It works together with the Cascade and Zones regulator kit.
1 extension pipe Ø 80 2 m long Cod.3.016837
for VICTRIX PRO 35/55/60/68/80 V2
1 extension pipe Ø 80 2 m long Cod.3.016837
for condensing boilers
2 x 45° Bend kit Ø 80/125 Cod.3.015248
2 x 45° bend kit Ø 160 Cod.3.024518
for VICTRIX PRO V2 and RAPAX 200/300 V3
4 extension pipes Ø 80 kit 0,5 m long Cod.3.014642
for condensing boilers
4 x 90° bends Ø 80 kit Cod.3.012091
for condensing boilers
45° bend Ø 80 kit Cod.3.012092
for condensing boilers
87° Bend kit Ø 80/125 Cod.3.015247
87° bend kit Ø 160 Cod.3.024517
For VICTRIX PRO V2 and RAPAX 200/300 V3
Additional exhaust manifold kit VICTRIX PRO 35/55/60/68/80 V2 Ø 160 with flue lock DN 80 Cod.3.034258
for connection of an additional boiler
Clapet valve kit Ø 80 in stainless steel Cod.3.033715
For VICTRIX PRO 35-55-60-68-80 V2.
Exhaust manifold kit VICTRIX PRO 35/55/60/68/80 V2 Ø 160 with flue lock DN 80 Cod.3.034257
for exhaust connection of two boilers in cascade
Extension pipe kit Ø 80/125 1 m long Cod.3.018667
For VICTRIX PRO 35/55/60/68/80 V2 and condensing boiler < 35 kW.
Extension pipe kit Ø 80/125 2 m long Cod.3.015246
for VICTRIX PRO 35/55/60/68/80 V2 and condensing boiler < 35 kW.
Extension pipe kit Ø 160 1 m long Cod.3.024516
For VICTRIX PRO V2 and RAPAX 200-300 V3.
Extension pipe Ø 160 kit 0,5 m long Cod.3.024659
For VICTRIX PRO V2 and RAPAX 200-300 V3.
Flashing Kit Ø 80/125 for flat roof Cod.3.015249
for VICTRIX PRO 35/55/60/68/80 V2
Gasket kit Ø 125 Cod.3.015345
Gasket kits 10 pcs. Ø 80 Ø 80 Cod.3.015378
Gasket kits 10 pcs. Ø 80 Ø 80/125 Cod.3.015343
Horizontal concentric kit Ø 80/125 Cod.3.033785
for VICTRIX PRO 35/55/60/68/80 V2
Horizontal kit Ø 80 Cod.3.015254
for VICTRIX PRO 35/55/60/68/80 V2 (to discharge in the chimney)
Horizontal kit Ø 80 Cod.3.015255
for VICTRIX PRO 35/55/60/68/80 V2 (to discharge horizontally)
Stub-pipe kit Ø80 Cod.3.033759
for air intake for VICTRIX PRO 35/55/60/68/80 V2 with B23 configuration
Twin pipes complete kit Ø 80/80 Cod.3.012002
for condensing boilers < 35 kW and VICTRIX PRO 35/55/60/68/80 V2 (color RAL 9010)
Vertical concentric kit Ø 80/125 Cod.3.033786
for VICTRIX PRO 35/55/60/68/80 V2
(black coloured, with converse for pitched roofs)
Vertical terminal outlet kit Ø 80 Cod.3.034579
VICTRIX PRO 35/55/60/68/80 V2 (to discharge at roof)
Vertical terminal outlet outdoor kit Ø 80 Cod.3.024295
(stainless steel) VICTRIX PRO 35/55/60/68/80 V2
(for outdoor) length 0.55m
Technical note: size is not adjustable
Adapter kit VICTRIX PRO 35/55/60/68/80 V2 Cod.3.023966
for replacement of VICTRIX 50 and 75 versions in single wall unit
configuration
Anti freeze protection kit -15 °C VICTRIX PRO V2 Cod.3.034125
Usable in outdoor installations for minimum temperature as low as -15 °C.
Condensate discharge pump kit Cod.3.020002
For single VICTRIX PRO V2
To be used in case of opposite slope between siphon and discharge
It can only be installed inside the building and outside the appliance
Condensate neutralizer kit until 80 kW Cod.3.033687
Condensate neutralizer until 180 kW Cod.3.033688
Condensate neutralizer until 1500 kW Cod.3.023662
necessary to neutralize the acidity of the condensation. Inclusive of
granulate.
Dirt separator kit for VICTRIX PRO 35/55/60/68/80 V2 in cascade Cod.3.033674
The kit includes connection manifolds and support
Dirt separator kit for single installation Cod.3.033673
For installation both on right and left side
Granulate for condensate neutralizer VICTRIX PRO V2 Cod.3.034920
For condensate neutralizer until 180 kW
Granulate kit for condensate neutralizer (25 kg) Cod.3.023663
Complete recharge for condensate neutralizer kit until 1500 kW
Hydraulic manifold kit G 2 ½” for 2 VICTRIX PRO 35/55/60/68/80 V2 in cascade Cod.3.032338
includes a 2-way valves, a 3-way interception valve and a non-return valve
for each generator.
Insulation as standard.
Hydraulic manifold kit G 2 ½” for additional VICTRIX PRO 35/55/60/68/80 V2 in cascade Cod.3.033669
in combination with kit 3.032338, it serves to connect from 3 to 5 VICTRIX
PRO V2 boilers in cascade installation (one kit required for each additional
boiler); includes a 2-way interception valve, a 3-way interception valve and
a non-return valve. Insulation as standard
Hydraulic manifold kit for VICTRIX PRO 35/55/60/68/80 V2 Cod.3.023951
Hydraulic manifold with safety kit for VICTRIX PRO V2 cabinet Cod.3.033681
The kit includes hydraulic manifold DN 100, safety kit and condensate discharge
manifold DN 50. The installer has to realise gas manifold based on design.
Hydraulic separator for 100 kW installations Cod.3.020839
Hydraulic separator for 200 kW installations Cod.3.021377
Hydraulic separator for 350 kW installations Cod.3.023965
Hydraulic separator for 400 kW installations Cod.3.021378
Hydraulic separator for 600 kW installations Cod.3.023962
Insulation as standard.
IPX4D protection box kit for cascade safety kit Cod.3.024038
IPX4D protection box kit for single boiler safety kit VICTRIX PRO V2 Cod.3.024028
Plate heat exchanger kit for cascade installation on the right side of VICTRIX PRO 35/55/60/68/80 V2 Cod.3.033678
The kit includes connecting pipes, air vent, discharge tap, filling taps and
connection to expansion vessel.
Plate heat exchanger kit for single installation on the right side of VICTRIX PRO 35/55/80 V2 Cod.3.033676
The kit includes connecting pipes, air vent, discharge tap, filling taps and
connection to expansion vessel
Probe kit for PT 1000 solar collector Cod.3.019374
Used to manage solar plant paired to boiler configurations with cascade
and zone regulator kit
Safety kit single boiler VICTRIX PRO V2 Cod.3.023949
Storage tank probe kit Cod.3.015268
Used to manage the temperature of the water tank unit paired, in boiler
rooms, with cascade and zone regulator kit
Three-way valve kit connection to a separate storage tank VICTRIX PRO V2 Cod.3.023950
VICTRIX PRO V2 Cabinet kit Cod.3.033680
it can be installed outdoor.
It includes 4 support feet that ensure stable installation and its handling by
forklift truck or transpallet to be positioned below the cabinet frame.
Alternatively, you can move the cabinet by means of 4 eyebolts in the upper
part.
The cabinet has a door that can be opened by 180 inclusive of lock.
“Free standing” support frame kit VICTRIX PRO 35/55/60/68/80 V2 Cod.3.032347
Designed to resolve installation situations in which the wall of the boiler
room is not usable.
With this modular construction, it is necessary to order a kit for every boiler
installed.
Approved also for installation outside the building.
Wall hung, modular condensing boiler for heating only.
Wide modulating ratio up to 5 boilers in cascade installation, high performances with reduced consumption thanks to the 1:10 modulation range and high efficiency, the new VICTRIX PRO V2 is the ideal solution for light commercial solutions in residential and commercial buildings. The new design, compact and linear, with a vertical sliding door protecting the control board, makes its installation easy even in residential buildings (according to the current regulations in force in each country).
VICTRIX PRO V2 can be used on the appropriate supporting modulation frame for floor standing installations. Certified for indoor and outdoor installations, even in unsheltered areas thanks to the IPX5D electric protection, the boiler is supplied with the -5 °C anti-freeze kit as standard.
Thanks to low emissions of carbon monoxide (CO) and nitrogen oxide (NOX), VICTRIX PRO V2 belongs to class 6, the most environmentally-friendly class established by the European standards (UNI EN 297 e UNI EN 483).
The new VICTRIX PRO V2 can work with natural gas, LPG and up to 20% blend of hydrogen.
CRONO 7 (weekly digital chronothermostat) Cod.3.021622
ON/OFF room thermostat.
CRONO 7 WIRELESS (wireless weekly digital chronothermostat) Cod.3.021624
Wireless ON/OFF room thermostat.
Cascade and zone regulator kit Cod.3.034119
It can manage 3 water distribution zones plus an external storage tank unit
and thermal solar for DHW production, both in standalone and cascade
configurations. It includes power supply connection for installation on a DIN
rail.
Clip-in for VICTRIX PRO V2 Cod.3.034122
To be used together with Cascade and Zones regulator kit (1 for each boiler).
Expansion kit for Cascade and Zones regulator kit Cod.3.034124
To be used to manage 1 additional zone (direct or mixed) up to a maximum
of 5.
External probe Cod.3.015266
For single installation of VICTRIX PRO V2.
For MAGIS COMBO V2, MAGIS PRO V2, MAGIS COMBO PLUS V2, MAGIS HERCULES PRO, MAGIS HERCULES PRO MINI/EH, MAGIS HERCULES MINI HYDRO, TRIO PACK ELECTRIC, TRIO HYDRO system ELECTRIC and MAGIS M/EH.
External probe kit (for cascade installation) Cod.3.024511
Paired with cascade and zone regulator kit, it optimizes energy
consumption by adjusting the plant delivery temperature for variable
temperature functioning
Flow probe kit Cod.3.015267
To be located on the delivery side of the plant, after the hydraulic
separator, it allows the cascade and zone regulator to manage the
delivery temperature of the plant or of the mixed zones available
Remote control for single VICTRIX PRO V2 Cod.3.020358
This is a modulating control unit that serves to optimize climatic
management of the temperature in rooms.
It can only be used on systems with a single temperature control.
System delivery probe kit for the boiler VICTRIX PRO V2 Cod.3.024245
Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.
Tele-management kit 2.0 Cod.3.034121
It works together with the Cascade and Zones regulator kit. It allows remote
management of the device with a dedicated APP.
Zone manager kit Cod.3.034120
Modulating temperature control, backlit display and remote management of
the zone. It works together with the Cascade and Zones regulator kit.
1 extension pipe Ø 80 2 m long Cod.3.016837
for VICTRIX PRO 35/55/60/68/80 V2
1 extension pipe Ø 80 2 m long Cod.3.016837
for condensing boilers
2 x 45° Bend kit Ø 80/125 Cod.3.015248
2 x 45° bend kit Ø 160 Cod.3.024518
for VICTRIX PRO V2 and RAPAX 200/300 V3
4 extension pipes Ø 80 kit 0,5 m long Cod.3.014642
for condensing boilers
4 x 90° bends Ø 80 kit Cod.3.012091
for condensing boilers
45° bend Ø 80 kit Cod.3.012092
for condensing boilers
87° Bend kit Ø 80/125 Cod.3.015247
87° bend kit Ø 160 Cod.3.024517
For VICTRIX PRO V2 and RAPAX 200/300 V3
Additional exhaust manifold kit VICTRIX PRO 35/55/60/68/80 V2 Ø 160 with flue lock DN 80 Cod.3.034258
for connection of an additional boiler
Clapet valve kit Ø 80 in stainless steel Cod.3.033715
For VICTRIX PRO 35-55-60-68-80 V2.
Exhaust manifold kit VICTRIX PRO 35/55/60/68/80 V2 Ø 160 with flue lock DN 80 Cod.3.034257
for exhaust connection of two boilers in cascade
Extension pipe kit Ø 80/125 1 m long Cod.3.018667
For VICTRIX PRO 35/55/60/68/80 V2 and condensing boiler < 35 kW.
Extension pipe kit Ø 80/125 2 m long Cod.3.015246
for VICTRIX PRO 35/55/60/68/80 V2 and condensing boiler < 35 kW.
Extension pipe kit Ø 160 1 m long Cod.3.024516
For VICTRIX PRO V2 and RAPAX 200-300 V3.
Extension pipe Ø 160 kit 0,5 m long Cod.3.024659
For VICTRIX PRO V2 and RAPAX 200-300 V3.
Flashing Kit Ø 80/125 for flat roof Cod.3.015249
for VICTRIX PRO 35/55/60/68/80 V2
Gasket kit Ø 125 Cod.3.015345
Gasket kits 10 pcs. Ø 80 Ø 80 Cod.3.015378
Gasket kits 10 pcs. Ø 80 Ø 80/125 Cod.3.015343
Horizontal concentric kit Ø 80/125 Cod.3.033785
for VICTRIX PRO 35/55/60/68/80 V2
Horizontal kit Ø 80 Cod.3.015254
for VICTRIX PRO 35/55/60/68/80 V2 (to discharge in the chimney)
Horizontal kit Ø 80 Cod.3.015255
for VICTRIX PRO 35/55/60/68/80 V2 (to discharge horizontally)
Stub-pipe kit Ø80 Cod.3.033759
for air intake for VICTRIX PRO 35/55/60/68/80 V2 with B23 configuration
Twin pipes complete kit Ø 80/80 Cod.3.012002
for condensing boilers < 35 kW and VICTRIX PRO 35/55/60/68/80 V2 (color RAL 9010)
Vertical concentric kit Ø 80/125 Cod.3.033786
for VICTRIX PRO 35/55/60/68/80 V2
(black coloured, with converse for pitched roofs)
Vertical terminal outlet kit Ø 80 Cod.3.034579
VICTRIX PRO 35/55/60/68/80 V2 (to discharge at roof)
Vertical terminal outlet outdoor kit Ø 80 Cod.3.024295
(stainless steel) VICTRIX PRO 35/55/60/68/80 V2
(for outdoor) length 0.55m
Technical note: size is not adjustable
Adapter kit VICTRIX PRO 35/55/60/68/80 V2 Cod.3.023966
for replacement of VICTRIX 50 and 75 versions in single wall unit
configuration
Anti freeze protection kit -15 °C VICTRIX PRO V2 Cod.3.034125
Usable in outdoor installations for minimum temperature as low as -15 °C.
Condensate discharge pump kit Cod.3.020002
For single VICTRIX PRO V2
To be used in case of opposite slope between siphon and discharge
It can only be installed inside the building and outside the appliance
Condensate neutralizer kit until 80 kW Cod.3.033687
Condensate neutralizer until 180 kW Cod.3.033688
Condensate neutralizer until 1500 kW Cod.3.023662
necessary to neutralize the acidity of the condensation. Inclusive of
granulate.
Dirt separator kit for VICTRIX PRO 35/55/60/68/80 V2 in cascade Cod.3.033674
The kit includes connection manifolds and support
Dirt separator kit for single installation Cod.3.033673
For installation both on right and left side
Granulate for condensate neutralizer VICTRIX PRO V2 Cod.3.034920
For condensate neutralizer until 180 kW
Granulate kit for condensate neutralizer (25 kg) Cod.3.023663
Complete recharge for condensate neutralizer kit until 1500 kW
Hydraulic manifold kit G 2 ½” for 2 VICTRIX PRO 35/55/60/68/80 V2 in cascade Cod.3.032338
includes a 2-way valves, a 3-way interception valve and a non-return valve
for each generator.
Insulation as standard.
Hydraulic manifold kit G 2 ½” for additional VICTRIX PRO 35/55/60/68/80 V2 in cascade Cod.3.033669
in combination with kit 3.032338, it serves to connect from 3 to 5 VICTRIX
PRO V2 boilers in cascade installation (one kit required for each additional
boiler); includes a 2-way interception valve, a 3-way interception valve and
a non-return valve. Insulation as standard
Hydraulic manifold kit for VICTRIX PRO 35/55/60/68/80 V2 Cod.3.023951
Hydraulic manifold with safety kit for VICTRIX PRO V2 cabinet Cod.3.033681
The kit includes hydraulic manifold DN 100, safety kit and condensate discharge
manifold DN 50. The installer has to realise gas manifold based on design.
Hydraulic separator for 100 kW installations Cod.3.020839
Hydraulic separator for 200 kW installations Cod.3.021377
Hydraulic separator for 350 kW installations Cod.3.023965
Hydraulic separator for 400 kW installations Cod.3.021378
Hydraulic separator for 600 kW installations Cod.3.023962
Insulation as standard.
IPX4D protection box kit for cascade safety kit Cod.3.024038
IPX4D protection box kit for single boiler safety kit VICTRIX PRO V2 Cod.3.024028
Plate heat exchanger kit for cascade installation on the right side of VICTRIX PRO 35/55/60/68/80 V2 Cod.3.033678
The kit includes connecting pipes, air vent, discharge tap, filling taps and
connection to expansion vessel.
Plate heat exchanger kit for single installation on the right side of VICTRIX PRO 35/55/80 V2 Cod.3.033676
The kit includes connecting pipes, air vent, discharge tap, filling taps and
connection to expansion vessel
Probe kit for PT 1000 solar collector Cod.3.019374
Used to manage solar plant paired to boiler configurations with cascade
and zone regulator kit
Safety kit single boiler VICTRIX PRO V2 Cod.3.023949
Storage tank probe kit Cod.3.015268
Used to manage the temperature of the water tank unit paired, in boiler
rooms, with cascade and zone regulator kit
Three-way valve kit connection to a separate storage tank VICTRIX PRO V2 Cod.3.023950
VICTRIX PRO V2 Cabinet kit Cod.3.033680
it can be installed outdoor.
It includes 4 support feet that ensure stable installation and its handling by
forklift truck or transpallet to be positioned below the cabinet frame.
Alternatively, you can move the cabinet by means of 4 eyebolts in the upper
part.
The cabinet has a door that can be opened by 180 inclusive of lock.
“Free standing” support frame kit VICTRIX PRO 35/55/60/68/80 V2 Cod.3.032347
Designed to resolve installation situations in which the wall of the boiler
room is not usable.
With this modular construction, it is necessary to order a kit for every boiler
installed.
Approved also for installation outside the building.