Technical data VICTRIX PRO 180 V2 EU |
|
|---|---|
| Code | 3.033864 |
| custom | Array |
| custom2 | Array |
| C.H. Energy class | A |
| Heat output ref. 80-60°C kW | 166,9 |
| Heat output ref. 50-30°C kW | 180,2 |
| Efficiency at nominal heat output ref. 80-60 °C | 98,2% |
| Efficiency at nominal heat output ref. 50-30 °C | 106,0% |
| Dimensions (HxWxD) mm | 1098 (1232) x 600 x 557 |
| Modulating heat output | 20 - 100% |
Technical data VICTRIX PRO 180 V2 EU |
|
|---|---|
| Code | 3.033864 |
| Product plus | HYDROGEN READY 20% |
| Product plus | BIM READY |
| C.H. Energy class | A |
| Heat output ref. 80-60°C kW | 166,9 |
| Heat output ref. 50-30°C kW | 180,2 |
| Efficiency at nominal heat output ref. 80-60 °C | 98,2% |
| Efficiency at nominal heat output ref. 50-30 °C | 106,0% |
| Dimensions (HxWxD) mm | 1098 (1232) x 600 x 557 |
| Modulating heat output | 20 - 100% |
Wall-hung modular condensing boiler for heating only
Designed for light commercial solutions in residential and commercial buildings, the VICTRIX PRO V2 has high performances with reduced energy consumption, thanks to its high seasonal efficiency and 1:10 modulation range.
The advanced electronics allow to control up to 15 units in simple cascade.
The new design, compact and linear, with a vertical sliding door protecting the control board, makes its installation easy even in residential buildings (according to the current regulations in force in each country).
The boiler can be wall-mounted or installed as a floor-standing unit using the dedicated support frame. Certified for both indoor and outdoor installation, including unsheltered locations, it features IPX5D electrical protection and is supplied as standard with a −5 °C antifreeze protection (-15°C with an optional kit).
With very low CO and NOx emissions, the VICTRIX PRO V2 belongs to the Class 6, the highest environmental performance class defined by the European standards.
The VICTRIX PRO V2 is compatible with natural gas, LPG and 20% blend of hydrogen.
Remote control for single VICTRIX PRO V2 Cod.3.020358
This is a modulating control unit that serves to optimize climatic
management of the temperature in rooms.
It can only be used on systems with a single temperature control.
Clip-in for VICTRIX PRO V2 Cod.3.034122
To be used together with Cascade and Zones regulator kit (1 for each boiler).
Expansion kit for Cascade and Zones regulator kit Cod.3.034124
To be used to manage 1 additional zone (direct or mixed) up to a maximum
of 5.
Zone manager kit Cod.3.034120
Modulating temperature control, backlit display and remote management of
the zone. It works together with the Cascade and Zones regulator kit.
CRONO 7 (weekly digital chronothermostat) Cod.3.021622
ON/OFF room thermostat.
CRONO 7 WIRELESS (wireless weekly digital chronothermostat) Cod.3.021624
Wireless ON/OFF room thermostat.
Cascade and zone regulator kit Cod.3.034119
It can manage 3 water distribution zones plus an external storage tank unit
and thermal solar for DHW production, both in standalone and cascade
configurations. It includes power supply connection for installation on a DIN
rail.
External probe Cod.3.015266
For single installation of VICTRIX PRO V2.
For MAGIS COMBO V2, MAGIS PRO V2, MAGIS COMBO PLUS V2, MAGIS HERCULES PRO, MAGIS HERCULES PRO MINI/EH, MAGIS HERCULES MINI HYDRO, TRIO PACK ELECTRIC, TRIO HYDRO system ELECTRIC and MAGIS M/EH.
Flow probe kit Cod.3.015267
To be located on the delivery side of the plant, after the hydraulic
separator, it allows the cascade and zone regulator to manage the
delivery temperature of the plant or of the mixed zones available
System delivery probe kit for the boiler VICTRIX PRO V2 Cod.3.024245
Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.
External probe kit (for cascade installation) Cod.3.024511
Paired with cascade and zone regulator kit, it optimizes energy
consumption by adjusting the plant delivery temperature for variable
temperature functioning
Tele-management kit 2.0 Cod.3.034121
It works together with the Cascade and Zones regulator kit. It allows remote
management of the device with a dedicated APP.
Terminal vertical outlet kit Ø 160 Cod.3.034554
For VICTRIX PRO 180 V2 2 (to discharge at roof)
Vertical terminal outlet outdoor kit Ø 160 (stainless steel) Cod.3.034555
For VICTRIX PRO 180 V2
(for outdoor) length 1m
Technical note: size is not adjustable
Horizontal kit Ø 160 Cod.3.034556
For VICTRIX PRO 180 V2 (to discharge in the chimney)
Horizontal kit Ø 160 Cod.3.034557
For VICTRIX PRO 180 V2 (to discharge horizontally)
4 extension pipes Ø 160 kit Cod.3.034559
For VICTRIX PRO 180 V2 0,5 m long
4 extension pipes Ø 160 kit Cod.3.034560
For VICTRIX PRO 180 V2 1 m long
4 extension pipes Ø 160 kit Cod.3.034561
For VICTRIX PRO 180 V2 2 m long
45° bend Ø 160 kit Cod.3.034562
For VICTRIX PRO 180 V2
4 x 90° bends Ø 160 kit Cod.3.034563
For VICTRIX PRO 180 V2
Stub-pipe kit Ø160 for air intake Cod.3.034565
for VICTRIX PRO 180 V2 with B23 configuration
Safety kit single boiler VICTRIX PRO V2 Cod.3.023949
Three-way valve kit connection to a separate storage tank VICTRIX PRO V2 Cod.3.023950
Hydraulic manifold kit for VICTRIX PRO 100/120/150 /180V2 Cod.3.023952
Specially sized for large thermal systems with high water content.
Equipped with sludge collection filter on the return pipe.
Insulation as standard
IPX4D protection box kit for single boiler safety kit VICTRIX PRO V2 Cod.3.024028
Anti freeze protection kit -15 °C VICTRIX PRO V2 Cod.3.034125
Usable in outdoor installations for minimum temperature as low as -15 °C.
Condensate neutralizer until 180 kW Cod.3.033688
Condensate neutralizer until 1500 kW Cod.3.023662
necessary to neutralize the acidity of the condensation. Inclusive of
granulate.
Granulate for condensate neutralizer VICTRIX PRO V2 Cod.3.034920
For condensate neutralizer until 180 kW
Granulate kit for condensate neutralizer (25 kg) Cod.3.023663
Complete recharge for condensate neutralizer kit until 1500 kW
Dirt separator kit for single installation Cod.3.033673
For installation both on right and left side
Plate heat exchanger kit for single installation on the right side of VICTRIX PRO 100/120/150/180 V2 Cod.3.033677
The kit includes connecting pipes, air vent, discharge tap, filling taps and
connection to expansion vessel
Hydraulic manifold kit DN 100 for 2 VICTRIX PRO 180 V2 in cascade Cod.3.034938
Hydraulic manifold kit DN 100 for additional VICTRIX PRO 180 V2 in cascade Cod.3.034939
in combination with kit 3.034938 it serves to connect from 3 to 5 VICTRIX
PRO V2 boilers in cascade installation (one kit required for each additional
boiler); includes a 2-way interception valve, a 3-way interception valve and
a non-return valve. Insulation as standard
Safety kit DN 100 for VICTRIX PRO 100/120/150/180 V2 in cascade Cod.3.023961
the kit includes thermometer, thermometer holder, lock, thermostat with
manual reset, connection tap for pressure gauge, manual reset pressure
switch, gas intercepting valve trap, expansion vessel connection and
pressure switch for minimum pressure. Insulation as standard
IPX4D protection box kit for cascade safety kit Cod.3.024038
Hydraulic separator for 100 kW installations Cod.3.020839
Hydraulic separator for 200 kW installations Cod.3.021377
Hydraulic separator for 350 kW installations Cod.3.023965
Hydraulic separator for 400 kW installations Cod.3.021378
Hydraulic separator for 600 kW installations Cod.3.023962
Insulation as standard.
Magnetic dirt separator kit for VICTRIX PRO 100/120/150/180 V2 in cascade Cod.3.033675
The kit includes connection manifolds and support.
Plate heat exchanger kit for cascade installation on the right side of VICTRIX PRO 100/120/150/180 V2 Cod.3.033679
The kit includes connecting pipes, air vent, discharge tap, filling taps and connection to expansion vessel
Storage tank probe kit Cod.3.015268
Used to manage the temperature of the water tank unit paired, in boiler
rooms, with cascade and zone regulator kit
Solar collector probe Cod.3.025467
Probe kit for PT 1000 solar collector Cod.3.019374
Used to manage solar plant paired to boiler configurations with cascade and zone regulator kit (3.021522)
Wall-hung modular condensing boiler for heating only
Designed for light commercial solutions in residential and commercial buildings, the VICTRIX PRO V2 has high performances with reduced energy consumption, thanks to its high seasonal efficiency and 1:10 modulation range.
The advanced electronics allow to control up to 15 units in simple cascade.
The new design, compact and linear, with a vertical sliding door protecting the control board, makes its installation easy even in residential buildings (according to the current regulations in force in each country).
The boiler can be wall-mounted or installed as a floor-standing unit using the dedicated support frame. Certified for both indoor and outdoor installation, including unsheltered locations, it features IPX5D electrical protection and is supplied as standard with a −5 °C antifreeze protection (-15°C with an optional kit).
With very low CO and NOx emissions, the VICTRIX PRO V2 belongs to the Class 6, the highest environmental performance class defined by the European standards.
The VICTRIX PRO V2 is compatible with natural gas, LPG and 20% blend of hydrogen.
Remote control for single VICTRIX PRO V2 Cod.3.020358
This is a modulating control unit that serves to optimize climatic
management of the temperature in rooms.
It can only be used on systems with a single temperature control.
Clip-in for VICTRIX PRO V2 Cod.3.034122
To be used together with Cascade and Zones regulator kit (1 for each boiler).
Expansion kit for Cascade and Zones regulator kit Cod.3.034124
To be used to manage 1 additional zone (direct or mixed) up to a maximum
of 5.
Zone manager kit Cod.3.034120
Modulating temperature control, backlit display and remote management of
the zone. It works together with the Cascade and Zones regulator kit.
CRONO 7 (weekly digital chronothermostat) Cod.3.021622
ON/OFF room thermostat.
CRONO 7 WIRELESS (wireless weekly digital chronothermostat) Cod.3.021624
Wireless ON/OFF room thermostat.
Cascade and zone regulator kit Cod.3.034119
It can manage 3 water distribution zones plus an external storage tank unit
and thermal solar for DHW production, both in standalone and cascade
configurations. It includes power supply connection for installation on a DIN
rail.
External probe Cod.3.015266
For single installation of VICTRIX PRO V2.
For MAGIS COMBO V2, MAGIS PRO V2, MAGIS COMBO PLUS V2, MAGIS HERCULES PRO, MAGIS HERCULES PRO MINI/EH, MAGIS HERCULES MINI HYDRO, TRIO PACK ELECTRIC, TRIO HYDRO system ELECTRIC and MAGIS M/EH.
Flow probe kit Cod.3.015267
To be located on the delivery side of the plant, after the hydraulic
separator, it allows the cascade and zone regulator to manage the
delivery temperature of the plant or of the mixed zones available
System delivery probe kit for the boiler VICTRIX PRO V2 Cod.3.024245
Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.
External probe kit (for cascade installation) Cod.3.024511
Paired with cascade and zone regulator kit, it optimizes energy
consumption by adjusting the plant delivery temperature for variable
temperature functioning
Tele-management kit 2.0 Cod.3.034121
It works together with the Cascade and Zones regulator kit. It allows remote
management of the device with a dedicated APP.
Terminal vertical outlet kit Ø 160 Cod.3.034554
For VICTRIX PRO 180 V2 2 (to discharge at roof)
Vertical terminal outlet outdoor kit Ø 160 (stainless steel) Cod.3.034555
For VICTRIX PRO 180 V2
(for outdoor) length 1m
Technical note: size is not adjustable
Horizontal kit Ø 160 Cod.3.034556
For VICTRIX PRO 180 V2 (to discharge in the chimney)
Horizontal kit Ø 160 Cod.3.034557
For VICTRIX PRO 180 V2 (to discharge horizontally)
4 extension pipes Ø 160 kit Cod.3.034559
For VICTRIX PRO 180 V2 0,5 m long
4 extension pipes Ø 160 kit Cod.3.034560
For VICTRIX PRO 180 V2 1 m long
4 extension pipes Ø 160 kit Cod.3.034561
For VICTRIX PRO 180 V2 2 m long
45° bend Ø 160 kit Cod.3.034562
For VICTRIX PRO 180 V2
4 x 90° bends Ø 160 kit Cod.3.034563
For VICTRIX PRO 180 V2
Stub-pipe kit Ø160 for air intake Cod.3.034565
for VICTRIX PRO 180 V2 with B23 configuration
Safety kit single boiler VICTRIX PRO V2 Cod.3.023949
Three-way valve kit connection to a separate storage tank VICTRIX PRO V2 Cod.3.023950
Hydraulic manifold kit for VICTRIX PRO 100/120/150 /180V2 Cod.3.023952
Specially sized for large thermal systems with high water content.
Equipped with sludge collection filter on the return pipe.
Insulation as standard
IPX4D protection box kit for single boiler safety kit VICTRIX PRO V2 Cod.3.024028
Anti freeze protection kit -15 °C VICTRIX PRO V2 Cod.3.034125
Usable in outdoor installations for minimum temperature as low as -15 °C.
Condensate neutralizer until 180 kW Cod.3.033688
Condensate neutralizer until 1500 kW Cod.3.023662
necessary to neutralize the acidity of the condensation. Inclusive of
granulate.
Granulate for condensate neutralizer VICTRIX PRO V2 Cod.3.034920
For condensate neutralizer until 180 kW
Granulate kit for condensate neutralizer (25 kg) Cod.3.023663
Complete recharge for condensate neutralizer kit until 1500 kW
Dirt separator kit for single installation Cod.3.033673
For installation both on right and left side
Plate heat exchanger kit for single installation on the right side of VICTRIX PRO 100/120/150/180 V2 Cod.3.033677
The kit includes connecting pipes, air vent, discharge tap, filling taps and
connection to expansion vessel
Hydraulic manifold kit DN 100 for 2 VICTRIX PRO 180 V2 in cascade Cod.3.034938
Hydraulic manifold kit DN 100 for additional VICTRIX PRO 180 V2 in cascade Cod.3.034939
in combination with kit 3.034938 it serves to connect from 3 to 5 VICTRIX
PRO V2 boilers in cascade installation (one kit required for each additional
boiler); includes a 2-way interception valve, a 3-way interception valve and
a non-return valve. Insulation as standard
Safety kit DN 100 for VICTRIX PRO 100/120/150/180 V2 in cascade Cod.3.023961
the kit includes thermometer, thermometer holder, lock, thermostat with
manual reset, connection tap for pressure gauge, manual reset pressure
switch, gas intercepting valve trap, expansion vessel connection and
pressure switch for minimum pressure. Insulation as standard
IPX4D protection box kit for cascade safety kit Cod.3.024038
Hydraulic separator for 100 kW installations Cod.3.020839
Hydraulic separator for 200 kW installations Cod.3.021377
Hydraulic separator for 350 kW installations Cod.3.023965
Hydraulic separator for 400 kW installations Cod.3.021378
Hydraulic separator for 600 kW installations Cod.3.023962
Insulation as standard.
Magnetic dirt separator kit for VICTRIX PRO 100/120/150/180 V2 in cascade Cod.3.033675
The kit includes connection manifolds and support.
Plate heat exchanger kit for cascade installation on the right side of VICTRIX PRO 100/120/150/180 V2 Cod.3.033679
The kit includes connecting pipes, air vent, discharge tap, filling taps and connection to expansion vessel
Storage tank probe kit Cod.3.015268
Used to manage the temperature of the water tank unit paired, in boiler
rooms, with cascade and zone regulator kit
Solar collector probe Cod.3.025467
Probe kit for PT 1000 solar collector Cod.3.019374
Used to manage solar plant paired to boiler configurations with cascade and zone regulator kit (3.021522)