VICTRIX PRO 120 V2 EU

Wall-hung modular condensing boiler for heating only
The customer service provides
prompt answers within 24 hours.
Wide modulating heat output
Ideal for energy efficiency upgrade
Possible installation in cascade

Technical data VICTRIX PRO 120 V2 EU

Code 3.033862
custom Array
custom2 Array
C.H. Energy class A
Heat output ref. 80-60°C kW 112,3
Heat output ref. 50-30°C kW 121,7
Efficiency at nominal heat output ref. 80-60 °C 98,1%
Efficiency at nominal heat output ref. 50-30 °C 106,3%
Dimensions (HxWxD) mm 1098 (1232) x 600 x 557
Modulating heat output 10 - 100%

Technical data VICTRIX PRO 120 V2 EU

Code 3.033862
Product plus HYDROGEN READY 20%
Product plus BIM READY
C.H. Energy class A
Heat output ref. 80-60°C kW 112,3
Heat output ref. 50-30°C kW 121,7
Efficiency at nominal heat output ref. 80-60 °C 98,1%
Efficiency at nominal heat output ref. 50-30 °C 106,3%
Dimensions (HxWxD) mm 1098 (1232) x 600 x 557
Modulating heat output 10 - 100%

Gallery

Wall hung, modular condensing boiler for heating only. 

Wide modulating ratio up to 5 boilers in cascade installation, high performances with reduced consumption thanks to the 1:10 modulation range and high efficiency, the new VICTRIX PRO V2 is the ideal solution for light commercial solutions in residential and commercial buildings. The new design, compact and linear, with a vertical sliding door protecting the control board, makes its installation easy even in residential buildings (according to the current regulations in force in each country).
VICTRIX PRO V2 can be used on the appropriate supporting modulation frame for floor standing installations. Certified for indoor and outdoor installations, even in unsheltered areas thanks to the IPX5D electric protection, the boiler is supplied with the -5 °C anti-freeze kit as standard.
Thanks to low emissions of carbon monoxide (CO) and nitrogen oxide (NOX), VICTRIX PRO V2 belongs to class 6, the most environmentally-friendly class established by the European standards (UNI EN 297 e UNI EN 483).

The new VICTRIX PRO V2 can work with natural gas, LPG and up to 20% blend of hydrogen.

...

CRONO 7 (weekly digital chronothermostat)   Cod.3.021622

ON/OFF room thermostat.

 

...

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)   Cod.3.021624

Wireless ON/OFF room thermostat.

 

 

...

Cascade and zone regulator kit   Cod.3.034119

It can manage 3 water distribution zones plus an external storage tank unit
and thermal solar for DHW production, both in standalone and cascade
configurations. It includes power supply connection for installation on a DIN
rail.

...

Clip-in for VICTRIX PRO V2   Cod.3.034122

To be used together with Cascade and Zones regulator kit (1 for each boiler).

...

Expansion kit for Cascade and Zones regulator kit   Cod.3.034124

To be used to manage 1 additional zone (direct or mixed) up to a maximum
of 5.

...

External probe   Cod.3.015266

For single installation of VICTRIX PRO V2.
For MAGIS COMBO V2, MAGIS PRO V2, MAGIS COMBO PLUS V2, MAGIS HERCULES PRO, MAGIS HERCULES PRO MINI/EH, MAGIS HERCULES MINI HYDRO, TRIO PACK ELECTRIC, TRIO HYDRO system ELECTRIC and MAGIS M/EH.

 

...

External probe kit (for cascade installation)   Cod.3.024511

Paired with cascade and zone regulator kit, it optimizes energy
consumption by adjusting the plant delivery temperature for variable
temperature functioning 

...

Flow probe kit   Cod.3.015267

To be located on the delivery side of the plant, after the hydraulic
separator, it allows the cascade and zone regulator to manage the
delivery temperature of the plant or of the mixed zones available

...

Remote control for single VICTRIX PRO V2   Cod.3.020358

This is a modulating control unit that serves to optimize climatic
management of the temperature in rooms.
It can only be used on systems with a single temperature control.

...

System delivery probe kit for the boiler VICTRIX PRO V2   Cod.3.024245

Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.

...

Tele-management kit 2.0   Cod.3.034121

It works together with the Cascade and Zones regulator kit. It allows remote
management of the device with a dedicated APP.

...

Zone manager kit   Cod.3.034120

Modulating temperature control, backlit display and remote management of
the zone. It works together with the Cascade and Zones regulator kit.

...

2 x 45° bend kit Ø 200 for flue manifold   Cod.3.024664

For installations in central heating systems with VICTRIX PRO V2.

...

2 x 45° bend kit Ø 250 for flue manifold   Cod.3.024669

For installations in central heating systems with VICTRIX PRO V2.

...

4 extension pipes Ø 100 kit 0,5 m long   Cod.3.031132

for VICTRIX PRO 100/120/150 V2

...

4 extension pipes Ø 100 kit 1 m long   Cod.3.031373

for VICTRIX PRO 100/120/150 V2

...

4 extension pipes Ø 100 kit 2 m long   Cod.3.032319

for VICTRIX PRO 100/120/150 V2

...

4 x 87° bends Ø 100 kit   Cod.3.032731

for VICTRIX PRO 100/120/150 V2

...

45° bend Ø 100 kit   Cod.3.032195

for VICTRIX PRO 100/120/150 V2

...

45° bend Ø 110/160 kit   Cod.3.031395

for VICTRIX PRO 100/120/150 V2

...

87° bend kit Ø 200 for flue manifold   Cod.3.024665

...

87° bend kit Ø 250 for flue manifold   Cod.3.024670

For installations in central heating systems with VICTRIX PRO V2.

...

87° bend Ø 110/160 kit   Cod.3.031396

for VICTRIX PRO 100/120/150 V2

...

Additional exhaust manifold kit VICTRIX PRO 100/120/150 V2 Ø 200   Cod.3.034260

Additional exhaust manifold kit Ø 200 with flue lock DN 125 for connection of an additional boiler

...

Additional exhaust manifold kit Ø 250 with flue lock DN 125 for 4 VICTRIX PRO 150 V2   Cod.3.034261

Additional exhaust manifold kit Ø 250 with flue lock DN 125 for 4 VICTRIX PRO 150 V2

...

Additional exhaust manifold kit Ø 250 with flue lock DN 125 for 5 VICTRIX PRO 150 V2   Cod.3.034262

Additional exhaust manifold kit Ø 250 with flue lock DN 125 for 5 VICTRIX PRO 150 V2

...

Clapet valve kit Ø 125 in stainless steel   Cod.3.033716

For VICTRIX PRO 100-120-150 V2.

...

Exhaust manifold kit Ø 200 VICTRIX PRO 100/120/150 V2   Cod.3.034259

Exhaust manifold kit Ø 200 with flue lock DN 125 for exhaust connection of two boilers in cascade.

...

Extension pipe kit Ø 110/160 1 m long   Cod.3.031397

for VICTRIX PRO 100/120/150 V2

...

Extension pipe kit Ø 110/160 2 m long   Cod.3.031398

for VICTRIX PRO 100/120/150 V2

...

Extension pipe Ø 200 kit 0,5 m long for flue manifold   Cod.3.024663

For installations in central heating systems with VICTRIX PRO V2.  

...

Extension pipe Ø 200 kit 1 m long for flue manifold   Cod.3.024662

For installations in central heating systems with VICTRIX PRO V2.

...

Extension pipe Ø 250 kit 1 m long for flue manifold   Cod.3.024668

For installations in central heating systems with VICTRIX PRO V2.

...

Gasket kit Ø 110   Cod.3.015344

...

Gasket kits 4 pcs. Ø 100   Cod.3.032732

...

Horizontal concentric kit Ø 110/160   Cod.3.033789

for VICTRIX PRO 100/120/150 V2

...

Horizontal kit Ø 100   Cod.3.032715

for VICTRIX PRO 100/120/150 V2 (to discharge in the chimney)

...

Horizontal kit Ø 100   Cod.3.032716

for VICTRIX PRO 100/120/150 V2 (to discharge horizontally)

...

Stub-pipe kit Ø100   Cod.3.033760

for air intake for VICTRIX PRO 100/120/150 V2 with
B23 configuration

...

Twin pipes complete kit Ø 100/100   Cod.3.032717

for VICTRIX PRO 100/120/150 V2 (color RAL 9010)

...

Vertical concentric kit Ø 110/160   Cod.3.033790

for VICTRIX PRO 100/120/150 V2
(black coloured, with converse for pitched roofs)

...

Vertical terminal outlet kit Ø 100   Cod.3.032713

For VICTRIX PRO 100/120/150 V2 (to discharge at roof)

...

Vertical terminal outlet outdoor kit Ø 100   Cod.3.032714

(stainless steel)
VICTRIX PRO 100/120/150 V2
(for outdoor) length 1m

...

Anti freeze protection kit -15 °C  VICTRIX PRO V2   Cod.3.034125

Usable in outdoor installations for minimum temperature as low as -15 °C.

...

Condensate discharge pump kit   Cod.3.020002

For single VICTRIX PRO V2

To be used in case of opposite slope between siphon and discharge
It can only be installed inside the building and outside the appliance

...

Condensate neutralizer until 180 kW   Cod.3.033688

Necessary to neutralize the acidity of the condensation. Inclusive of granulate.
...

Condensate neutralizer until 1500 kW   Cod.3.023662

necessary to neutralize the acidity of the condensation. Inclusive of
granulate.

...

Cover kit IPX5D   Cod.3.033671

for VICTRIX PRO 100/120 V2

...

Cover kit IPX5D   Cod.3.033672

for VICTRIX PRO 150 V2

...

Dirt separator kit for single installation   Cod.3.033673

For installation both on right and left side

...

Granulate for condensate neutralizer VICTRIX PRO V2   Cod.3.034920

For condensate neutralizer until 180 kW

...

Granulate kit for condensate neutralizer (25 kg)   Cod.3.023663

Complete recharge for condensate neutralizer kit until 1500 kW

...

Hydraulic manifold kit DN 100 for 2 VICTRIX PRO 100/120/150 V2 in cascade   Cod.3.033667

kit includes a 2 way interception valve, a 3-way interception valve and a
non-return valve for each generator.
Insulation as standard

...

Hydraulic manifold kit DN 100 for additional VICTRIX PRO 100/120/150 V2 in cascade   Cod.3.033668

in combination with kit 3.033667 serves to connect from 3 to 5 VICTRIX
PRO V2 boilers in cascade installation (one kit required for each additional
boiler); includes a 2-way interception valve, a 3-way interception valve and
a non-return valve.
Insulation as standard

...

Hydraulic manifold kit for VICTRIX PRO 100/120/150 /180V2   Cod.3.023952

Specially sized for large thermal systems with high water content.
Equipped with sludge collection filter on the return pipe.
Insulation as standard

...

Hydraulic manifold with safety kit for VICTRIX PRO V2 cabinet   Cod.3.033681

The kit includes hydraulic manifold DN 100, safety kit and condensate discharge
manifold DN 50. The installer has to realise gas manifold based on design. 

...

Hydraulic separator for 100 kW installations   Cod.3.020839

Separator with G 2 ½" threaded connectors.
Insulation as standard.
...

Hydraulic separator for 200 kW installations   Cod.3.021377

Separator with G 2 ½" threaded connectors.
Insulation as standard.
...

Hydraulic separator for 350 kW installations   Cod.3.023965

Separator with threaded connectors - DN 100.
Insulation as standard.
...

Hydraulic separator for 400 kW installations   Cod.3.021378

Separator with G 2 ½" threaded connectors on boiler side - DN 100 on system side.
Insulation as standard.
...

Hydraulic separator for 600 kW installations   Cod.3.023962

Separator with threaded connectors - DN 100.
Insulation as standard.
...

IPX4D protection box kit for cascade safety kit   Cod.3.024038

...

IPX4D protection box kit for single boiler safety kit VICTRIX PRO V2   Cod.3.024028

...

Magnetic dirt separator kit for VICTRIX PRO 100/120/150/180 V2 in cascade   Cod.3.033675

 The kit includes connection manifolds and support.

...

Plate heat exchanger kit for cascade installation on the right side of VICTRIX PRO 100/120/150/180 V2   Cod.3.033679

The kit includes connecting pipes, air vent, discharge tap, filling taps and connection to expansion vessel

...

Plate heat exchanger kit for single installation on the right side of VICTRIX PRO 100/120/150/180 V2   Cod.3.033677

The kit includes connecting pipes, air vent, discharge tap, filling taps and
connection to expansion vessel 

...

Probe kit for PT 1000 solar collector   Cod.3.019374

Used to manage solar plant paired to boiler configurations with cascade
and zone regulator kit

...

Safety kit DN 100 for VICTRIX PRO 100/120/150/180 V2 in cascade   Cod.3.023961

the kit includes thermometer, thermometer holder, lock, thermostat with
manual reset, connection tap for pressure gauge, manual reset pressure
switch, gas intercepting valve trap, expansion vessel connection and
pressure switch for minimum pressure. Insulation as standard

...

Safety kit single boiler VICTRIX PRO V2   Cod.3.023949

The kit includes thermometer, thermometer holder, lock, thermostat with manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure. Insulation as standard.
...

Storage tank probe kit   Cod.3.015268

Used to manage the temperature of the water tank unit paired, in boiler
rooms, with cascade and zone regulator kit

...

Three-way valve kit connection to a separate storage tank VICTRIX PRO V2   Cod.3.023950

The kit includes the storage tank probe. The power supply is 230 Vac.
Insulation as standard.
...

VICTRIX PRO V2 Cabinet kit   Cod.3.033680

it can be installed outdoor.
It includes 4 support feet that ensure stable installation and its handling by
forklift truck or transpallet to be positioned below the cabinet frame.
Alternatively, you can move the cabinet by means of 4 eyebolts in the upper
part.
The cabinet has a door that can be opened by 180 inclusive of lock.

...

“Free standing” support frame kit VICTRIX PRO 100/120/150 V2   Cod.3.033686

Designed to resolve installation situations in which the wall of the boiler
room is not usable.
With this modular construction, it is necessary to order a kit for every boiler
installed.
Approved also for installation outside the building

Wall hung, modular condensing boiler for heating only. 

Wide modulating ratio up to 5 boilers in cascade installation, high performances with reduced consumption thanks to the 1:10 modulation range and high efficiency, the new VICTRIX PRO V2 is the ideal solution for light commercial solutions in residential and commercial buildings. The new design, compact and linear, with a vertical sliding door protecting the control board, makes its installation easy even in residential buildings (according to the current regulations in force in each country).
VICTRIX PRO V2 can be used on the appropriate supporting modulation frame for floor standing installations. Certified for indoor and outdoor installations, even in unsheltered areas thanks to the IPX5D electric protection, the boiler is supplied with the -5 °C anti-freeze kit as standard.
Thanks to low emissions of carbon monoxide (CO) and nitrogen oxide (NOX), VICTRIX PRO V2 belongs to class 6, the most environmentally-friendly class established by the European standards (UNI EN 297 e UNI EN 483).

The new VICTRIX PRO V2 can work with natural gas, LPG and up to 20% blend of hydrogen.

...

CRONO 7 (weekly digital chronothermostat)   Cod.3.021622

ON/OFF room thermostat.

 

...

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)   Cod.3.021624

Wireless ON/OFF room thermostat.

 

 

...

Cascade and zone regulator kit   Cod.3.034119

It can manage 3 water distribution zones plus an external storage tank unit
and thermal solar for DHW production, both in standalone and cascade
configurations. It includes power supply connection for installation on a DIN
rail.

...

Clip-in for VICTRIX PRO V2   Cod.3.034122

To be used together with Cascade and Zones regulator kit (1 for each boiler).

...

Expansion kit for Cascade and Zones regulator kit   Cod.3.034124

To be used to manage 1 additional zone (direct or mixed) up to a maximum
of 5.

...

External probe   Cod.3.015266

For single installation of VICTRIX PRO V2.
For MAGIS COMBO V2, MAGIS PRO V2, MAGIS COMBO PLUS V2, MAGIS HERCULES PRO, MAGIS HERCULES PRO MINI/EH, MAGIS HERCULES MINI HYDRO, TRIO PACK ELECTRIC, TRIO HYDRO system ELECTRIC and MAGIS M/EH.

 

...

External probe kit (for cascade installation)   Cod.3.024511

Paired with cascade and zone regulator kit, it optimizes energy
consumption by adjusting the plant delivery temperature for variable
temperature functioning 

...

Flow probe kit   Cod.3.015267

To be located on the delivery side of the plant, after the hydraulic
separator, it allows the cascade and zone regulator to manage the
delivery temperature of the plant or of the mixed zones available

...

Remote control for single VICTRIX PRO V2   Cod.3.020358

This is a modulating control unit that serves to optimize climatic
management of the temperature in rooms.
It can only be used on systems with a single temperature control.

...

System delivery probe kit for the boiler VICTRIX PRO V2   Cod.3.024245

Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.

...

Tele-management kit 2.0   Cod.3.034121

It works together with the Cascade and Zones regulator kit. It allows remote
management of the device with a dedicated APP.

...

Zone manager kit   Cod.3.034120

Modulating temperature control, backlit display and remote management of
the zone. It works together with the Cascade and Zones regulator kit.

...

2 x 45° bend kit Ø 200 for flue manifold   Cod.3.024664

For installations in central heating systems with VICTRIX PRO V2.

...

2 x 45° bend kit Ø 250 for flue manifold   Cod.3.024669

For installations in central heating systems with VICTRIX PRO V2.

...

4 extension pipes Ø 100 kit 0,5 m long   Cod.3.031132

for VICTRIX PRO 100/120/150 V2

...

4 extension pipes Ø 100 kit 1 m long   Cod.3.031373

for VICTRIX PRO 100/120/150 V2

...

4 extension pipes Ø 100 kit 2 m long   Cod.3.032319

for VICTRIX PRO 100/120/150 V2

...

4 x 87° bends Ø 100 kit   Cod.3.032731

for VICTRIX PRO 100/120/150 V2

...

45° bend Ø 100 kit   Cod.3.032195

for VICTRIX PRO 100/120/150 V2

...

45° bend Ø 110/160 kit   Cod.3.031395

for VICTRIX PRO 100/120/150 V2

...

87° bend kit Ø 200 for flue manifold   Cod.3.024665

...

87° bend kit Ø 250 for flue manifold   Cod.3.024670

For installations in central heating systems with VICTRIX PRO V2.

...

87° bend Ø 110/160 kit   Cod.3.031396

for VICTRIX PRO 100/120/150 V2

...

Additional exhaust manifold kit VICTRIX PRO 100/120/150 V2 Ø 200   Cod.3.034260

Additional exhaust manifold kit Ø 200 with flue lock DN 125 for connection of an additional boiler

...

Additional exhaust manifold kit Ø 250 with flue lock DN 125 for 4 VICTRIX PRO 150 V2   Cod.3.034261

Additional exhaust manifold kit Ø 250 with flue lock DN 125 for 4 VICTRIX PRO 150 V2

...

Additional exhaust manifold kit Ø 250 with flue lock DN 125 for 5 VICTRIX PRO 150 V2   Cod.3.034262

Additional exhaust manifold kit Ø 250 with flue lock DN 125 for 5 VICTRIX PRO 150 V2

...

Clapet valve kit Ø 125 in stainless steel   Cod.3.033716

For VICTRIX PRO 100-120-150 V2.

...

Exhaust manifold kit Ø 200 VICTRIX PRO 100/120/150 V2   Cod.3.034259

Exhaust manifold kit Ø 200 with flue lock DN 125 for exhaust connection of two boilers in cascade.

...

Extension pipe kit Ø 110/160 1 m long   Cod.3.031397

for VICTRIX PRO 100/120/150 V2

...

Extension pipe kit Ø 110/160 2 m long   Cod.3.031398

for VICTRIX PRO 100/120/150 V2

...

Extension pipe Ø 200 kit 0,5 m long for flue manifold   Cod.3.024663

For installations in central heating systems with VICTRIX PRO V2.  

...

Extension pipe Ø 200 kit 1 m long for flue manifold   Cod.3.024662

For installations in central heating systems with VICTRIX PRO V2.

...

Extension pipe Ø 250 kit 1 m long for flue manifold   Cod.3.024668

For installations in central heating systems with VICTRIX PRO V2.

...

Gasket kit Ø 110   Cod.3.015344

...

Gasket kits 4 pcs. Ø 100   Cod.3.032732

...

Horizontal concentric kit Ø 110/160   Cod.3.033789

for VICTRIX PRO 100/120/150 V2

...

Horizontal kit Ø 100   Cod.3.032715

for VICTRIX PRO 100/120/150 V2 (to discharge in the chimney)

...

Horizontal kit Ø 100   Cod.3.032716

for VICTRIX PRO 100/120/150 V2 (to discharge horizontally)

...

Stub-pipe kit Ø100   Cod.3.033760

for air intake for VICTRIX PRO 100/120/150 V2 with
B23 configuration

...

Twin pipes complete kit Ø 100/100   Cod.3.032717

for VICTRIX PRO 100/120/150 V2 (color RAL 9010)

...

Vertical concentric kit Ø 110/160   Cod.3.033790

for VICTRIX PRO 100/120/150 V2
(black coloured, with converse for pitched roofs)

...

Vertical terminal outlet kit Ø 100   Cod.3.032713

For VICTRIX PRO 100/120/150 V2 (to discharge at roof)

...

Vertical terminal outlet outdoor kit Ø 100   Cod.3.032714

(stainless steel)
VICTRIX PRO 100/120/150 V2
(for outdoor) length 1m

...

Anti freeze protection kit -15 °C  VICTRIX PRO V2   Cod.3.034125

Usable in outdoor installations for minimum temperature as low as -15 °C.

...

Condensate discharge pump kit   Cod.3.020002

For single VICTRIX PRO V2

To be used in case of opposite slope between siphon and discharge
It can only be installed inside the building and outside the appliance

...

Condensate neutralizer until 180 kW   Cod.3.033688

Necessary to neutralize the acidity of the condensation. Inclusive of granulate.
...

Condensate neutralizer until 1500 kW   Cod.3.023662

necessary to neutralize the acidity of the condensation. Inclusive of
granulate.

...

Cover kit IPX5D   Cod.3.033671

for VICTRIX PRO 100/120 V2

...

Cover kit IPX5D   Cod.3.033672

for VICTRIX PRO 150 V2

...

Dirt separator kit for single installation   Cod.3.033673

For installation both on right and left side

...

Granulate for condensate neutralizer VICTRIX PRO V2   Cod.3.034920

For condensate neutralizer until 180 kW

...

Granulate kit for condensate neutralizer (25 kg)   Cod.3.023663

Complete recharge for condensate neutralizer kit until 1500 kW

...

Hydraulic manifold kit DN 100 for 2 VICTRIX PRO 100/120/150 V2 in cascade   Cod.3.033667

kit includes a 2 way interception valve, a 3-way interception valve and a
non-return valve for each generator.
Insulation as standard

...

Hydraulic manifold kit DN 100 for additional VICTRIX PRO 100/120/150 V2 in cascade   Cod.3.033668

in combination with kit 3.033667 serves to connect from 3 to 5 VICTRIX
PRO V2 boilers in cascade installation (one kit required for each additional
boiler); includes a 2-way interception valve, a 3-way interception valve and
a non-return valve.
Insulation as standard

...

Hydraulic manifold kit for VICTRIX PRO 100/120/150 /180V2   Cod.3.023952

Specially sized for large thermal systems with high water content.
Equipped with sludge collection filter on the return pipe.
Insulation as standard

...

Hydraulic manifold with safety kit for VICTRIX PRO V2 cabinet   Cod.3.033681

The kit includes hydraulic manifold DN 100, safety kit and condensate discharge
manifold DN 50. The installer has to realise gas manifold based on design. 

...

Hydraulic separator for 100 kW installations   Cod.3.020839

Separator with G 2 ½" threaded connectors.
Insulation as standard.
...

Hydraulic separator for 200 kW installations   Cod.3.021377

Separator with G 2 ½" threaded connectors.
Insulation as standard.
...

Hydraulic separator for 350 kW installations   Cod.3.023965

Separator with threaded connectors - DN 100.
Insulation as standard.
...

Hydraulic separator for 400 kW installations   Cod.3.021378

Separator with G 2 ½" threaded connectors on boiler side - DN 100 on system side.
Insulation as standard.
...

Hydraulic separator for 600 kW installations   Cod.3.023962

Separator with threaded connectors - DN 100.
Insulation as standard.
...

IPX4D protection box kit for cascade safety kit   Cod.3.024038

...

IPX4D protection box kit for single boiler safety kit VICTRIX PRO V2   Cod.3.024028

...

Magnetic dirt separator kit for VICTRIX PRO 100/120/150/180 V2 in cascade   Cod.3.033675

 The kit includes connection manifolds and support.

...

Plate heat exchanger kit for cascade installation on the right side of VICTRIX PRO 100/120/150/180 V2   Cod.3.033679

The kit includes connecting pipes, air vent, discharge tap, filling taps and connection to expansion vessel

...

Plate heat exchanger kit for single installation on the right side of VICTRIX PRO 100/120/150/180 V2   Cod.3.033677

The kit includes connecting pipes, air vent, discharge tap, filling taps and
connection to expansion vessel 

...

Probe kit for PT 1000 solar collector   Cod.3.019374

Used to manage solar plant paired to boiler configurations with cascade
and zone regulator kit

...

Safety kit DN 100 for VICTRIX PRO 100/120/150/180 V2 in cascade   Cod.3.023961

the kit includes thermometer, thermometer holder, lock, thermostat with
manual reset, connection tap for pressure gauge, manual reset pressure
switch, gas intercepting valve trap, expansion vessel connection and
pressure switch for minimum pressure. Insulation as standard

...

Safety kit single boiler VICTRIX PRO V2   Cod.3.023949

The kit includes thermometer, thermometer holder, lock, thermostat with manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure. Insulation as standard.
...

Storage tank probe kit   Cod.3.015268

Used to manage the temperature of the water tank unit paired, in boiler
rooms, with cascade and zone regulator kit

...

Three-way valve kit connection to a separate storage tank VICTRIX PRO V2   Cod.3.023950

The kit includes the storage tank probe. The power supply is 230 Vac.
Insulation as standard.
...

VICTRIX PRO V2 Cabinet kit   Cod.3.033680

it can be installed outdoor.
It includes 4 support feet that ensure stable installation and its handling by
forklift truck or transpallet to be positioned below the cabinet frame.
Alternatively, you can move the cabinet by means of 4 eyebolts in the upper
part.
The cabinet has a door that can be opened by 180 inclusive of lock.

...

“Free standing” support frame kit VICTRIX PRO 100/120/150 V2   Cod.3.033686

Designed to resolve installation situations in which the wall of the boiler
room is not usable.
With this modular construction, it is necessary to order a kit for every boiler
installed.
Approved also for installation outside the building

Related products

VICTRIX PRO 100 V2 EU
Wall-hung modular condensing boiler for heating only

Contacts

Contact us
Customer Care