MAGIS PRO 16 V2 T
prompt answers within 24 hours.
Technical data MAGIS PRO 16 V2 T |
|
|---|---|
| Code | 3.030668 |
| C.H. Energy class at 55 °C | A++ |
| C.H. Energy class at 35 °C | A+++ |
| Heating output kW | 16,00 |
| Cooling output kW | 11,20 |
| Internal Unit (HxWxD) mm | 780 x 440 x 340 |
| External Unit (HxWxD) mm | 1420 x 940 x 384 |
| Refrigerant gas | R410A |
| COP | 4,20 |
| EER | 3,62 |
| External unit weight (kg) | 100,0 |
| Hydronic unit weight (kg) | 38,5 |
Technical data MAGIS PRO 16 V2 T |
|
|---|---|
| Code | 3.030668 |
| C.H. Energy class at 55 °C | A++ |
| C.H. Energy class at 35 °C | A+++ |
| Heating output kW | 16,00 |
| Cooling output kW | 11,20 |
| Internal Unit (HxWxD) mm | 780 x 440 x 340 |
| External Unit (HxWxD) mm | 1420 x 940 x 384 |
| Refrigerant gas | R410A |
| COP | 4,20 |
| EER | 3,62 |
| External unit weight (kg) | 100,0 |
| Hydronic unit weight (kg) | 38,5 |
Spilt type reversible air-to-water inverter driven heat pump system composed by an outdoor unit and an indoor hydronic unit
MAGIS PRO V2 heat pump system range are air-to-water appliances, designed to exploit outdoor air as renewable energy source. Such a kind of appliances are the ideal solution for central heating (maximum delivery temperature equal to 55 °C), cooling and domestic hot water production, thanks to the possible coupling with a separate storage tank unit. The “PRO" designation underlines the particular degreee of competence of the professional people involved in the design and installation process, to whom such a kind of technical solution is addressed; for instance, the completion of the refrigerant circuit and the connection between outdoor unit and the hydronic one, implies the posses for the installer of a spefic qualification (the so called F-Gas licence).
- Pre-loaded refrigerant fluid R410A
- High COP and EER values
- Maximum delivery temperature 55 °C
- Pre-arranged to manage up to 3 zones system
- Inverter driven compressor allows wide power-modulation range and low current absortion, succeeding in high level performances for more comfortable indoor climatic conditions
- Domestic-purpose-suit systems, ideal in new, high energy class buildings, even when located in extremely cold areas, with very low outdoor-winter-temperatures
MAGIS PRO V2 can be installed in stand alone configuration, or combined with a boiler and other renewable energy sources in integrated or hybrid, compact systems, working in central heating, cooling and/or DHW production.
DOMINUS V2 interface kit Cod.3.034903
For hybrid and full electric solutions, Victrix Superior, Hercules range, Victrix Tera V3, Victrix Extra and Maior.
Dimensions (H=113,5 mm x W=123,5 mm x D=33,5 mm).
Remote Control Panel Cod.3.030863
System controller Cod.3.021522
Electronic controller with a microprocessor designed to be a "single manager" for integrated systems (e.g., boilers, heat pumps, and solar thermal systems).
The system manager allows you to select and activate the most convenient heat source based on the set environmental and economic parameters. It features a backlit display. Power must be supplied via a 48 VDC or 24 VAC – 50 Hz transformer (not included).
Mod-bus temperature and humidity sensor Cod.3.030992
To be used with radiant systems that also work in cooling mode
Room hygrostat Cod.3.023302
To be used with radiant systems that also work in cooling mode.
CRONO 7 (weekly digital chronothermostat) Cod.3.021622
ON/OFF room thermostat.
CRONO 7 WIRELESS (wireless weekly digital chronothermostat) Cod.3.021624
Wireless ON/OFF room thermostat.
Relay board kit Cod.3.015350
Zone control unit V2 kit Cod.3.030912
Control unit for external circulators/zone valves to manage 3 zones (2 mixed and 1 direct).
2 relays board kit Cod.3.026302
To be installed for the deumidifiers management without in absence of system manager kit.
Dedicated to MAGIS PRO V2 and MAGIS COMBO V2
External probe Cod.3.015266
For single installation of VICTRIX PRO V2.
For MAGIS COMBO V2, MAGIS PRO V2, MAGIS COMBO PLUS V2, MAGIS HERCULES PRO, MAGIS HERCULES PRO MINI/EH, MAGIS HERCULES MINI HYDRO, TRIO PACK ELECTRIC, TRIO HYDRO system ELECTRIC and MAGIS M/EH.
NTC contact probe for storage tank Cod.3.019375
Allows to check the DHW temperature of a Storage Tank Unit or puffer.
Provided as per standard on all Storage Tank Units in the catalogue (except UB 300/550/750 V2).
System delivery probe kit Cod.3.030913
Low temperature safety thermostat kit Cod.3.019229
For generators set to low temperature.
Connection kit for R410A circuit Cod.3.026089
2 zones kit (1 mixed and 1 direct) Cod.3.031695
For MAGIS PRO 12-14-16 V2, MAGIS COMBO/PLUS 12-14-16 V2, MAGIS HERCULES MINI HYDRO 12 and MAGIS M 12-16 TOP.
Vertical inertial storage tank 75 litre Cod.3.027288
OMNISTOR 300 Cod.3.027910
The storage tanks are equipped with:
• 1 stainless steel coils water/water heat exchanger with oversized coil
• 2 probe-supports and NTC probe for Immergas heat pump connection
• Thermometer
• Double magnesium anode
• Suitable flexible insulation which can be disassembled (6 cm thick on OMNISTOR 300 and 8 cm thick on OMNISTOR 500)
• Pre-arranged to fix pump station to the body of the storage tank with option kit (maximum 4 solar flat plate-collectors)
• Pre-arranged to double electronic anode (option) code 3.025003
OMNISTOR 500 Cod.3.027911
The storage tanks are equipped with:
• 1 stainless steel coils water/water heat exchanger with oversized coil
• 2 probe-supports and NTC probe for Immergas heat pump connection
• Thermometer
• Double magnesium anode
• Suitable flexible insulation which can be disassembled (6 cm thick on OMNISTOR 300 and 8 cm thick on OMNISTOR 500)
• Pre-arranged to fix pump station to the body of the storage tank with option kit (maximum 4 solar flat plate-collectors)
• Pre-arranged to double electronic anode (option) code 3.025003
Double electronic anode kit Cod.3.025003
2 kW electric resistance kit Cod.3.020861
For INOXSTOR 200-300-500 V2, OMNISTOR 300-500, UB 550-750 V2 and UB PRO SOL.
Power supply 230 or 400 Vac.
5 kW electric resistance kit Cod.3.020862
For UB 1000-1500 V2, UB 750 V2 and UB PRO SOL.
Power supply 230 or 400 Vac.
HYDRO 3 V2 Cod.3.033625
HYDRO 4 V2 Cod.3.033626
HYDRO FS 200 Cod.3.028500
HYDRO FS 400 Cod.3.028501
HYDRO FS 600 Cod.3.028502
HYDRO FS 800 Cod.3.028503
HYDRO FS 1000 Cod.3.028505
Dehumidifier kit Cod.3.021529
Dehumidifier front grille kit Cod.3.022147
Dehumidifier back frame kit Cod.3.022146
ZENITAIR MONO Cod.3.030601
External cover kit with acoustical insulation for ZENITAIR-MONO Cod.3.030636
Wall mounting brackets L 700 mm Cod.3.034758
For outdoor unit of MAGIS COMBO V2, MAGIS COMBO PLUS V2, TRIO PACK, TRIO HYDRO, MAGIS HERCULES PRO, MAGIS PRO V2, MAGIS HERCULES PRO MINI, MAGIS HERCULES MINI HYDRO, THOR, GOTHA and MULTI 18-27.
3 kW integration electric resistance kit for MAGIS PRO V2 Cod.3.030991
For heat pump only plants with MAGIS PRO V2, 3 kW (to be installed inside of the hydronic unit).
Electric power supply 230V-50Hz single phase + earthing
Anti freeze protection kit -15 °C Cod.3.017324
Anti freeze protection kit -15 °C
For TT versions, VICTRIX SUPERIOR/PLUS, VICTRIX ZEUS, VICTRIX EXA, TERA VIP, VICTRIX TERA/PLUS, OMNIA, MAGIS PRO V2 and MAGIS COMBO V2.
3-way valve kit Cod.3.020632
Spilt type reversible air-to-water inverter driven heat pump system composed by an outdoor unit and an indoor hydronic unit
MAGIS PRO V2 heat pump system range are air-to-water appliances, designed to exploit outdoor air as renewable energy source. Such a kind of appliances are the ideal solution for central heating (maximum delivery temperature equal to 55 °C), cooling and domestic hot water production, thanks to the possible coupling with a separate storage tank unit. The “PRO" designation underlines the particular degreee of competence of the professional people involved in the design and installation process, to whom such a kind of technical solution is addressed; for instance, the completion of the refrigerant circuit and the connection between outdoor unit and the hydronic one, implies the posses for the installer of a spefic qualification (the so called F-Gas licence).
- Pre-loaded refrigerant fluid R410A
- High COP and EER values
- Maximum delivery temperature 55 °C
- Pre-arranged to manage up to 3 zones system
- Inverter driven compressor allows wide power-modulation range and low current absortion, succeeding in high level performances for more comfortable indoor climatic conditions
- Domestic-purpose-suit systems, ideal in new, high energy class buildings, even when located in extremely cold areas, with very low outdoor-winter-temperatures
MAGIS PRO V2 can be installed in stand alone configuration, or combined with a boiler and other renewable energy sources in integrated or hybrid, compact systems, working in central heating, cooling and/or DHW production.
DOMINUS V2 interface kit Cod.3.034903
For hybrid and full electric solutions, Victrix Superior, Hercules range, Victrix Tera V3, Victrix Extra and Maior.
Dimensions (H=113,5 mm x W=123,5 mm x D=33,5 mm).
Remote Control Panel Cod.3.030863
System controller Cod.3.021522
Electronic controller with a microprocessor designed to be a "single manager" for integrated systems (e.g., boilers, heat pumps, and solar thermal systems).
The system manager allows you to select and activate the most convenient heat source based on the set environmental and economic parameters. It features a backlit display. Power must be supplied via a 48 VDC or 24 VAC – 50 Hz transformer (not included).
Mod-bus temperature and humidity sensor Cod.3.030992
To be used with radiant systems that also work in cooling mode
Room hygrostat Cod.3.023302
To be used with radiant systems that also work in cooling mode.
CRONO 7 (weekly digital chronothermostat) Cod.3.021622
ON/OFF room thermostat.
CRONO 7 WIRELESS (wireless weekly digital chronothermostat) Cod.3.021624
Wireless ON/OFF room thermostat.
Relay board kit Cod.3.015350
Zone control unit V2 kit Cod.3.030912
Control unit for external circulators/zone valves to manage 3 zones (2 mixed and 1 direct).
2 relays board kit Cod.3.026302
To be installed for the deumidifiers management without in absence of system manager kit.
Dedicated to MAGIS PRO V2 and MAGIS COMBO V2
External probe Cod.3.015266
For single installation of VICTRIX PRO V2.
For MAGIS COMBO V2, MAGIS PRO V2, MAGIS COMBO PLUS V2, MAGIS HERCULES PRO, MAGIS HERCULES PRO MINI/EH, MAGIS HERCULES MINI HYDRO, TRIO PACK ELECTRIC, TRIO HYDRO system ELECTRIC and MAGIS M/EH.
NTC contact probe for storage tank Cod.3.019375
Allows to check the DHW temperature of a Storage Tank Unit or puffer.
Provided as per standard on all Storage Tank Units in the catalogue (except UB 300/550/750 V2).
System delivery probe kit Cod.3.030913
Low temperature safety thermostat kit Cod.3.019229
For generators set to low temperature.
Connection kit for R410A circuit Cod.3.026089
2 zones kit (1 mixed and 1 direct) Cod.3.031695
For MAGIS PRO 12-14-16 V2, MAGIS COMBO/PLUS 12-14-16 V2, MAGIS HERCULES MINI HYDRO 12 and MAGIS M 12-16 TOP.
Vertical inertial storage tank 75 litre Cod.3.027288
OMNISTOR 300 Cod.3.027910
The storage tanks are equipped with:
• 1 stainless steel coils water/water heat exchanger with oversized coil
• 2 probe-supports and NTC probe for Immergas heat pump connection
• Thermometer
• Double magnesium anode
• Suitable flexible insulation which can be disassembled (6 cm thick on OMNISTOR 300 and 8 cm thick on OMNISTOR 500)
• Pre-arranged to fix pump station to the body of the storage tank with option kit (maximum 4 solar flat plate-collectors)
• Pre-arranged to double electronic anode (option) code 3.025003
OMNISTOR 500 Cod.3.027911
The storage tanks are equipped with:
• 1 stainless steel coils water/water heat exchanger with oversized coil
• 2 probe-supports and NTC probe for Immergas heat pump connection
• Thermometer
• Double magnesium anode
• Suitable flexible insulation which can be disassembled (6 cm thick on OMNISTOR 300 and 8 cm thick on OMNISTOR 500)
• Pre-arranged to fix pump station to the body of the storage tank with option kit (maximum 4 solar flat plate-collectors)
• Pre-arranged to double electronic anode (option) code 3.025003
Double electronic anode kit Cod.3.025003
2 kW electric resistance kit Cod.3.020861
For INOXSTOR 200-300-500 V2, OMNISTOR 300-500, UB 550-750 V2 and UB PRO SOL.
Power supply 230 or 400 Vac.
5 kW electric resistance kit Cod.3.020862
For UB 1000-1500 V2, UB 750 V2 and UB PRO SOL.
Power supply 230 or 400 Vac.
HYDRO 3 V2 Cod.3.033625
HYDRO 4 V2 Cod.3.033626
HYDRO FS 200 Cod.3.028500
HYDRO FS 400 Cod.3.028501
HYDRO FS 600 Cod.3.028502
HYDRO FS 800 Cod.3.028503
HYDRO FS 1000 Cod.3.028505
Dehumidifier kit Cod.3.021529
Dehumidifier front grille kit Cod.3.022147
Dehumidifier back frame kit Cod.3.022146
ZENITAIR MONO Cod.3.030601
External cover kit with acoustical insulation for ZENITAIR-MONO Cod.3.030636
Wall mounting brackets L 700 mm Cod.3.034758
For outdoor unit of MAGIS COMBO V2, MAGIS COMBO PLUS V2, TRIO PACK, TRIO HYDRO, MAGIS HERCULES PRO, MAGIS PRO V2, MAGIS HERCULES PRO MINI, MAGIS HERCULES MINI HYDRO, THOR, GOTHA and MULTI 18-27.
3 kW integration electric resistance kit for MAGIS PRO V2 Cod.3.030991
For heat pump only plants with MAGIS PRO V2, 3 kW (to be installed inside of the hydronic unit).
Electric power supply 230V-50Hz single phase + earthing
Anti freeze protection kit -15 °C Cod.3.017324
Anti freeze protection kit -15 °C
For TT versions, VICTRIX SUPERIOR/PLUS, VICTRIX ZEUS, VICTRIX EXA, TERA VIP, VICTRIX TERA/PLUS, OMNIA, MAGIS PRO V2 and MAGIS COMBO V2.