Technical data MAGIS PRO 16 V2 T

Code 3.030668
C.H. Energy class at 55 °C A++
C.H. Energy class at 35 °C A+++
Heating output kW 16,00
Cooling output kW 11,20
Internal Unit (HxWxD) mm 780 x 440 x 340
External Unit (HxWxD) mm 1420 x 940 x 384
Refrigerant gas R410A
COP 4,20
EER 3,62
External unit weight (kg) 100,0
Hydronic unit weight (kg) 38,5

Technical data MAGIS PRO 16 V2 T

Code 3.030668
C.H. Energy class at 55 °C A++
C.H. Energy class at 35 °C A+++
Heating output kW 16,00
Cooling output kW 11,20
Internal Unit (HxWxD) mm 780 x 440 x 340
External Unit (HxWxD) mm 1420 x 940 x 384
Refrigerant gas R410A
COP 4,20
EER 3,62
External unit weight (kg) 100,0
Hydronic unit weight (kg) 38,5

Gallery

Spilt type reversible air-to-water inverter driven heat pump system composed by an outdoor unit and an indoor hydronic unit

MAGIS PRO V2 heat pump system range are air-to-water appliances, designed to exploit outdoor air as renewable energy source.  Such a kind of appliances are the ideal solution for central heating (maximum delivery temperature equal to 55 °C), cooling and domestic hot water production, thanks to the possible coupling  with a separate storage tank unit. The “PRO" designation underlines the particular degreee of competence of the professional people involved in the design and installation process, to whom such a kind of technical solution is addressed; for instance, the completion of the refrigerant circuit and the connection between outdoor unit and the hydronic one, implies the posses for the installer of a spefic qualification (the so called F-Gas licence).

  • Pre-loaded refrigerant fluid R410A
  • High COP and EER values
  • Maximum delivery temperature 55 °C
  • Pre-arranged to manage up to 3 zones system
  • Inverter driven compressor allows wide power-modulation range and low current absortion, succeeding in high level performances for more comfortable indoor climatic conditions
  • Domestic-purpose-suit systems, ideal in new, high energy class buildings, even when located in extremely cold areas, with very low outdoor-winter-temperatures

MAGIS PRO V2 can be installed in stand alone configuration, or combined with a boiler and other renewable energy sources in integrated or hybrid, compact systems, working in central heating, cooling and/or DHW production.

...

DOMINUS V2 interface kit   Cod.3.034903

For hybrid and full electric solutions, Victrix Superior, Hercules range, Victrix Tera V3, Victrix Extra and Maior.
Dimensions (H=113,5 mm x W=123,5 mm x D=33,5 mm).

...

Remote Control Panel   Cod.3.030863

Modulating chronotermostat, remote control with temperature/humidity sensor
 
...

System controller   Cod.3.021522

Electronic controller with a microprocessor designed to be a "single manager" for integrated systems (e.g., boilers, heat pumps, and solar thermal systems).
The system manager allows you to select and activate the most convenient heat source based on the set environmental and economic parameters. It features a backlit display. Power must be supplied via a 48 VDC or 24 VAC – 50 Hz transformer (not included).

...

Mod-bus temperature and humidity sensor   Cod.3.030992

To be used with radiant systems that also work in cooling mode 

 

...

Room hygrostat   Cod.3.023302

To be used with radiant systems that also work in cooling mode.

...

CRONO 7 (weekly digital chronothermostat)   Cod.3.021622

ON/OFF room thermostat.

 

...

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)   Cod.3.021624

Wireless ON/OFF room thermostat.

 

 

...

Relay board kit   Cod.3.015350

Allows interface between zone valves and CARV2 or SUPER CAR, to send an alarm signal, to manage external pump etc.
 
To be installed inside boilers < 35 kW, except VICTRIX OMNIA and VICTRIX TERA V3.
To be installed inside internal unit of MAGIS COMBO V2, MAGIS PRO V2 and UCI EUREKA.
...

Zone control unit V2 kit   Cod.3.030912

Control unit for external circulators/zone valves to manage 3 zones (2 mixed and 1 direct).

...

2 relays board kit   Cod.3.026302

To be installed for the deumidifiers management without in absence of system manager kit.

Dedicated to MAGIS PRO V2 and MAGIS COMBO V2

 

 

...

External probe   Cod.3.015266

For single installation of VICTRIX PRO V2.
For MAGIS COMBO V2, MAGIS PRO V2, MAGIS COMBO PLUS V2, MAGIS HERCULES PRO, MAGIS HERCULES PRO MINI/EH, MAGIS HERCULES MINI HYDRO, TRIO PACK ELECTRIC, TRIO HYDRO system ELECTRIC and MAGIS M/EH.

 

...

NTC contact probe for storage tank   Cod.3.019375

Allows to check the DHW temperature of a Storage Tank Unit or puffer.
Provided as per standard on all Storage Tank Units in the catalogue (except UB 300/550/750 V2).

...

System delivery probe kit   Cod.3.030913

...

Low temperature safety thermostat kit   Cod.3.019229

For generators set to low temperature.

...

Connection kit for R410A circuit   Cod.3.026089

To connect refrigerant gas circuit where internal unit of MAGIS COMBO/PLUS 12-14-16 V2 e MAGIS PRO 12-14-16 V2 is installed to the wall 
...

2 zones kit (1 mixed and 1 direct)   Cod.3.031695

For MAGIS PRO 12-14-16 V2, MAGIS COMBO/PLUS 12-14-16 V2, MAGIS HERCULES MINI HYDRO 12 and MAGIS M 12-16 TOP.

...

Vertical inertial storage tank 75 litre   Cod.3.027288

Wall-hung (with bracket option kit) or floor-standing installation.
...

OMNISTOR 300   Cod.3.027910

The range of new OMNISTOR stainless steel storage tanks, is ideal to contain domestic hot water with an inspection flange at the lower part.
The storage tanks are equipped with:
• 1 stainless steel coils water/water heat exchanger with oversized coil
• 2 probe-supports and NTC probe for Immergas heat pump connection
• Thermometer
• Double magnesium anode
• Suitable flexible insulation which can be disassembled (6 cm thick on OMNISTOR 300 and 8 cm thick on OMNISTOR 500)
• Pre-arranged to fix pump station to the body of the storage tank with option kit (maximum 4 solar flat plate-collectors)
• Pre-arranged to double electronic anode (option) code 3.025003
 
Ideal for connection to heat pumps.
...

OMNISTOR 500   Cod.3.027911

The range of new OMNISTOR stainless steel storage tanks, is ideal to contain domestic hot water with an inspection flange at the lower part.
The storage tanks are equipped with:
• 1 stainless steel coils water/water heat exchanger with oversized coil
• 2 probe-supports and NTC probe for Immergas heat pump connection
• Thermometer
• Double magnesium anode
• Suitable flexible insulation which can be disassembled (6 cm thick on OMNISTOR 300 and 8 cm thick on OMNISTOR 500)
• Pre-arranged to fix pump station to the body of the storage tank with option kit (maximum 4 solar flat plate-collectors)
• Pre-arranged to double electronic anode (option) code 3.025003
 
Ideal for connection to heat pumps.
...

Double electronic anode kit   Cod.3.025003

For OMNISTOR, INOXSTOR V2, MAGIS HERCULES PRO, MAGIS HERCULES PRO MINI and MAGIS HERCULES MINI HYDRO.
 
 
 
 
...

2 kW electric resistance kit   Cod.3.020861

For INOXSTOR 200-300-500 V2, OMNISTOR 300-500, UB 550-750 V2 and UB PRO SOL.

Power supply 230 or 400 Vac.

...

5 kW electric resistance kit   Cod.3.020862

For UB 1000-1500 V2, UB 750 V2 and UB PRO SOL.

Power supply 230 or 400 Vac.

...

HYDRO 3 V2   Cod.3.033625

Wall-hung hydronic fancoil with LCD remote control and 3-way valve with micro switch on-off, as standard 
...

HYDRO 4 V2   Cod.3.033626

Wall-hung hydronic fancoil with LCD remote control and 3-way valve with micro switch on-off, as standard 
...

HYDRO FS 200   Cod.3.028500

Floor standing hydronic fancoil 
 
 
 
...

HYDRO FS 400   Cod.3.028501

Floor standing hydronic fancoil
 
...

HYDRO FS 600   Cod.3.028502

Floor standing hydronic fancoil 
 
 
...

HYDRO FS 800   Cod.3.028503

Floor standing hydronic fancoil 
 
 
...

HYDRO FS 1000   Cod.3.028505

Floor standing hydronic fancoil 
 
...

HYDRO IN 200   Cod.3.029841

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 400   Cod.3.029842

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 600   Cod.3.029843

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 800   Cod.3.029844

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 1000   Cod.3.029845

Wall and ceiling built-in hydronic fancoil
 
 
 
...

Dehumidifier kit   Cod.3.021529

Designed for radiant panel cooling systems pairing, the dehumidifier helps keep indoor humidity levels under control, preventing the formation of condensation on walls, floors, or ceilings.
Only for recessed installation with codes 3.022146 and 3.022147

 

...

Dehumidifier front grille kit   Cod.3.022147

...

Dehumidifier back frame kit   Cod.3.022146

...

ZENITAIR MONO   Cod.3.030601

Decentralised mechanical ventilation unit, easy to install, with alternate flow and heat recovery core.
Multifunction remote controller, with LCD display to visualise the status of the unit supplied as standard.
 
 
 
 
...

External cover kit with acoustical insulation for ZENITAIR-MONO   Cod.3.030636

Anti-insect net and anti-wind in pre-painted steel, alternative to the one available with ZENITAIR-MONO.
 
 
 
 
...

Wall mounting brackets L 700 mm   Cod.3.034758

For outdoor unit of MAGIS COMBO V2, MAGIS COMBO PLUS V2, TRIO PACK, TRIO HYDRO, MAGIS HERCULES PRO, MAGIS PRO V2, MAGIS HERCULES PRO MINI, MAGIS HERCULES MINI HYDRO, THOR, GOTHA and MULTI 18-27.

 

...

3 kW integration electric resistance kit for MAGIS PRO V2   Cod.3.030991

For heat pump only plants with MAGIS PRO V2, 3 kW (to be installed inside of the hydronic unit).
Electric power supply 230V-50Hz single phase + earthing

...

Anti freeze protection kit -15 °C   Cod.3.017324

Anti freeze protection kit -15 °C  
For TT versions, VICTRIX SUPERIOR/PLUS, VICTRIX ZEUS, VICTRIX EXA, TERA VIP, VICTRIX TERA/PLUS, OMNIA, MAGIS PRO V2 and MAGIS COMBO V2.

...

3-way valve kit   Cod.3.020632

Spilt type reversible air-to-water inverter driven heat pump system composed by an outdoor unit and an indoor hydronic unit

MAGIS PRO V2 heat pump system range are air-to-water appliances, designed to exploit outdoor air as renewable energy source.  Such a kind of appliances are the ideal solution for central heating (maximum delivery temperature equal to 55 °C), cooling and domestic hot water production, thanks to the possible coupling  with a separate storage tank unit. The “PRO" designation underlines the particular degreee of competence of the professional people involved in the design and installation process, to whom such a kind of technical solution is addressed; for instance, the completion of the refrigerant circuit and the connection between outdoor unit and the hydronic one, implies the posses for the installer of a spefic qualification (the so called F-Gas licence).

  • Pre-loaded refrigerant fluid R410A
  • High COP and EER values
  • Maximum delivery temperature 55 °C
  • Pre-arranged to manage up to 3 zones system
  • Inverter driven compressor allows wide power-modulation range and low current absortion, succeeding in high level performances for more comfortable indoor climatic conditions
  • Domestic-purpose-suit systems, ideal in new, high energy class buildings, even when located in extremely cold areas, with very low outdoor-winter-temperatures

MAGIS PRO V2 can be installed in stand alone configuration, or combined with a boiler and other renewable energy sources in integrated or hybrid, compact systems, working in central heating, cooling and/or DHW production.

...

DOMINUS V2 interface kit   Cod.3.034903

For hybrid and full electric solutions, Victrix Superior, Hercules range, Victrix Tera V3, Victrix Extra and Maior.
Dimensions (H=113,5 mm x W=123,5 mm x D=33,5 mm).

...

Remote Control Panel   Cod.3.030863

Modulating chronotermostat, remote control with temperature/humidity sensor
 
...

System controller   Cod.3.021522

Electronic controller with a microprocessor designed to be a "single manager" for integrated systems (e.g., boilers, heat pumps, and solar thermal systems).
The system manager allows you to select and activate the most convenient heat source based on the set environmental and economic parameters. It features a backlit display. Power must be supplied via a 48 VDC or 24 VAC – 50 Hz transformer (not included).

...

Mod-bus temperature and humidity sensor   Cod.3.030992

To be used with radiant systems that also work in cooling mode 

 

...

Room hygrostat   Cod.3.023302

To be used with radiant systems that also work in cooling mode.

...

CRONO 7 (weekly digital chronothermostat)   Cod.3.021622

ON/OFF room thermostat.

 

...

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)   Cod.3.021624

Wireless ON/OFF room thermostat.

 

 

...

Relay board kit   Cod.3.015350

Allows interface between zone valves and CARV2 or SUPER CAR, to send an alarm signal, to manage external pump etc.
 
To be installed inside boilers < 35 kW, except VICTRIX OMNIA and VICTRIX TERA V3.
To be installed inside internal unit of MAGIS COMBO V2, MAGIS PRO V2 and UCI EUREKA.
...

Zone control unit V2 kit   Cod.3.030912

Control unit for external circulators/zone valves to manage 3 zones (2 mixed and 1 direct).

...

2 relays board kit   Cod.3.026302

To be installed for the deumidifiers management without in absence of system manager kit.

Dedicated to MAGIS PRO V2 and MAGIS COMBO V2

 

 

...

External probe   Cod.3.015266

For single installation of VICTRIX PRO V2.
For MAGIS COMBO V2, MAGIS PRO V2, MAGIS COMBO PLUS V2, MAGIS HERCULES PRO, MAGIS HERCULES PRO MINI/EH, MAGIS HERCULES MINI HYDRO, TRIO PACK ELECTRIC, TRIO HYDRO system ELECTRIC and MAGIS M/EH.

 

...

NTC contact probe for storage tank   Cod.3.019375

Allows to check the DHW temperature of a Storage Tank Unit or puffer.
Provided as per standard on all Storage Tank Units in the catalogue (except UB 300/550/750 V2).

...

System delivery probe kit   Cod.3.030913

...

Low temperature safety thermostat kit   Cod.3.019229

For generators set to low temperature.

...

Connection kit for R410A circuit   Cod.3.026089

To connect refrigerant gas circuit where internal unit of MAGIS COMBO/PLUS 12-14-16 V2 e MAGIS PRO 12-14-16 V2 is installed to the wall 
...

2 zones kit (1 mixed and 1 direct)   Cod.3.031695

For MAGIS PRO 12-14-16 V2, MAGIS COMBO/PLUS 12-14-16 V2, MAGIS HERCULES MINI HYDRO 12 and MAGIS M 12-16 TOP.

...

Vertical inertial storage tank 75 litre   Cod.3.027288

Wall-hung (with bracket option kit) or floor-standing installation.
...

OMNISTOR 300   Cod.3.027910

The range of new OMNISTOR stainless steel storage tanks, is ideal to contain domestic hot water with an inspection flange at the lower part.
The storage tanks are equipped with:
• 1 stainless steel coils water/water heat exchanger with oversized coil
• 2 probe-supports and NTC probe for Immergas heat pump connection
• Thermometer
• Double magnesium anode
• Suitable flexible insulation which can be disassembled (6 cm thick on OMNISTOR 300 and 8 cm thick on OMNISTOR 500)
• Pre-arranged to fix pump station to the body of the storage tank with option kit (maximum 4 solar flat plate-collectors)
• Pre-arranged to double electronic anode (option) code 3.025003
 
Ideal for connection to heat pumps.
...

OMNISTOR 500   Cod.3.027911

The range of new OMNISTOR stainless steel storage tanks, is ideal to contain domestic hot water with an inspection flange at the lower part.
The storage tanks are equipped with:
• 1 stainless steel coils water/water heat exchanger with oversized coil
• 2 probe-supports and NTC probe for Immergas heat pump connection
• Thermometer
• Double magnesium anode
• Suitable flexible insulation which can be disassembled (6 cm thick on OMNISTOR 300 and 8 cm thick on OMNISTOR 500)
• Pre-arranged to fix pump station to the body of the storage tank with option kit (maximum 4 solar flat plate-collectors)
• Pre-arranged to double electronic anode (option) code 3.025003
 
Ideal for connection to heat pumps.
...

Double electronic anode kit   Cod.3.025003

For OMNISTOR, INOXSTOR V2, MAGIS HERCULES PRO, MAGIS HERCULES PRO MINI and MAGIS HERCULES MINI HYDRO.
 
 
 
 
...

2 kW electric resistance kit   Cod.3.020861

For INOXSTOR 200-300-500 V2, OMNISTOR 300-500, UB 550-750 V2 and UB PRO SOL.

Power supply 230 or 400 Vac.

...

5 kW electric resistance kit   Cod.3.020862

For UB 1000-1500 V2, UB 750 V2 and UB PRO SOL.

Power supply 230 or 400 Vac.

...

HYDRO 3 V2   Cod.3.033625

Wall-hung hydronic fancoil with LCD remote control and 3-way valve with micro switch on-off, as standard 
...

HYDRO 4 V2   Cod.3.033626

Wall-hung hydronic fancoil with LCD remote control and 3-way valve with micro switch on-off, as standard 
...

HYDRO FS 200   Cod.3.028500

Floor standing hydronic fancoil 
 
 
 
...

HYDRO FS 400   Cod.3.028501

Floor standing hydronic fancoil
 
...

HYDRO FS 600   Cod.3.028502

Floor standing hydronic fancoil 
 
 
...

HYDRO FS 800   Cod.3.028503

Floor standing hydronic fancoil 
 
 
...

HYDRO FS 1000   Cod.3.028505

Floor standing hydronic fancoil 
 
...

HYDRO IN 200   Cod.3.029841

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 400   Cod.3.029842

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 600   Cod.3.029843

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 800   Cod.3.029844

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 1000   Cod.3.029845

Wall and ceiling built-in hydronic fancoil
 
 
 
...

Dehumidifier kit   Cod.3.021529

Designed for radiant panel cooling systems pairing, the dehumidifier helps keep indoor humidity levels under control, preventing the formation of condensation on walls, floors, or ceilings.
Only for recessed installation with codes 3.022146 and 3.022147

 

...

Dehumidifier front grille kit   Cod.3.022147

...

Dehumidifier back frame kit   Cod.3.022146

...

ZENITAIR MONO   Cod.3.030601

Decentralised mechanical ventilation unit, easy to install, with alternate flow and heat recovery core.
Multifunction remote controller, with LCD display to visualise the status of the unit supplied as standard.
 
 
 
 
...

External cover kit with acoustical insulation for ZENITAIR-MONO   Cod.3.030636

Anti-insect net and anti-wind in pre-painted steel, alternative to the one available with ZENITAIR-MONO.
 
 
 
 
...

Wall mounting brackets L 700 mm   Cod.3.034758

For outdoor unit of MAGIS COMBO V2, MAGIS COMBO PLUS V2, TRIO PACK, TRIO HYDRO, MAGIS HERCULES PRO, MAGIS PRO V2, MAGIS HERCULES PRO MINI, MAGIS HERCULES MINI HYDRO, THOR, GOTHA and MULTI 18-27.

 

...

3 kW integration electric resistance kit for MAGIS PRO V2   Cod.3.030991

For heat pump only plants with MAGIS PRO V2, 3 kW (to be installed inside of the hydronic unit).
Electric power supply 230V-50Hz single phase + earthing

...

Anti freeze protection kit -15 °C   Cod.3.017324

Anti freeze protection kit -15 °C  
For TT versions, VICTRIX SUPERIOR/PLUS, VICTRIX ZEUS, VICTRIX EXA, TERA VIP, VICTRIX TERA/PLUS, OMNIA, MAGIS PRO V2 and MAGIS COMBO V2.

...

3-way valve kit   Cod.3.020632

Related products

MAGIS PRO 14 V2 T
Air-water inverter three-phase heat pump
MAGIS PRO 16 V2
Air-water inverter mono-phase heat pump
MAGIS PRO 12 V2 T
Air-water inverter three-phase heat pump

Contacts

Contact us
Customer Care